Airflow Distribution

Airflow Distribution Products

UPSITE KoldLok Integral Grommet

Designed to seal openings in newly raised floor cutouts before the installation of communications or power cabling. Based on measurements at multiple data centers, on average 48% of valuable conditioned air is not reaching the air intake of IT equipment due to unsealed floor openings. This lost air, known as bypass airflow, contributes to IT equipment hot spots, cooling unit inefficiencies, and increasing infrastructure costs.

 

 

UPSITE Blanking Panel

Designed to effectively seal openings in IT equipment cabinets and control airflow for optimized cooling effectiveness. The HotLok® Blanking Panel reduces hot spots and bypass airflow by preventing equipment exhaust air or hot aisle air from migrating to the conditioned air intake stream at the front of the cabinet.

 

 

UPSITE Bi-Directional Doors

The AisleLok Bi-Directional Doors are a key component in Upsite’s AisleLok Modular Containment solution. The doors can be used with or without the AisleLok Rack Top Baffles; however, for the maximum benefit, both products are recommended.

 

 

 

UPSITE Rack Top Angle Baffle

The AisleLok® Rack Top Baffles are a key component of Upsite’s AisleLok Modular Containment solution and are available in two configurations: Angular (30° from horizontal) and Vertical (90° from horizontal)

 

 

 

UPSITE Magnetic Under Rack Panel

The Magnetic Under Rack Panel by Upsite is a quick and easy way to improve airflow management by either blocking bypass airflow or exhaust air recirculation. It employs a unique sealing technology which allows easy, tool-less modifications for just the right placement and height. It’s a perfect complement to existing blanking panels and accommodates thermal efficiencies in the data center.

 

UPSITE Acrycell Sealing Tape

AisleLok® Acrycell Sealing Tape is the premium choice for sealing gaps and openings in the data center including room perimeter, floor openings, under cabinets, between racks, and around CRAC units. It has a revolutionary sealing technology which significantly reduces costly bypass airflow, increasing usable cooling unit capacity, and ensuring maximized efficiency from HVAC equipment.

 

 

TRIAD Chamfer Panel

Chamfer 56% open area airflow panels are designed to provide maximum airflow distribution that fits into any new or existing raised floor system.  All chamfer panels include our patented stratification fin – one of the hallmarks of Triad panels.  This fin allows you to direct the flow of air where you need it, eliminating hotspots and areas with poor air circulation.

 

 

TRIAD Aluminum Panel

Featuring a durable 55% open area perforated design, our cast aluminum panel is our most economical option and is designed to fit into most common flooring systems.

Get Started Today

We are experts in the critical data center environment. Contact us to schedule your next cleaning, to inquire about regular maintenance programs, or to learn about other products and services that will keep your data center operating at maximum efficiency.